Simon XT User Guide
23
Smoke Detector Locations
• Before mounting alarms, program (learn) them into memory and do a sensor test from the
alarm’s intended location to ensure good RF communication to the panel.
• Locate the alarm in environmentally controlled areas where the temperature range is
between 40 and 100°F (5 and 38°C) and the humidity is between 0 and 90% noncondensing.
• Locate alarms away from the ventilation sources that can prevent smoke from reaching the alarm.
• Locate ceiling mounted alarms in the center of the room or hallway, at least 4 in. (10cm)
away from any walls or partitions.
• Locate wall mounted alarms so the top of the alarm is 4 to 12 in. (10 to 31cm) below the
ceiling.
• In rooms with sloped, peaked, or gabled ceilings, locate alarms 3 ft. (0.9 m) down or away
from the highest point of the ceiling.
• When mounting to suspended ceiling tile, the tile must be secured with the appropriate
fasteners to prevent tile removal.
Note: Do not mount the alarm to the metal runners of suspended ceiling grids. The metal runners can draw the magnet’s eld away from the
alarm’s reed switch and cause a false tamper alarm.
Your floor plan
Use the following guidelines when drawing your oor plan:
• Show all building levels.
• Show exits from each room (two exits per room are recommended).
• Show the location of all security system components.
• Show the location of any re extinguisher
Required Smoke Detector
Optional Smoke Detector
Bedroom
Bedroom
Bedroom
Bedroom
Bedroom
Bedroom
Bedroom
TV Room
Living
Room
Dining
Room
Dining
Room
Dining
Room
Bedroom Bedroom
Recreation Room
Bedroom
Basement
Kitchen
Kitchen
Living Room
Living Room
Living Room
Basement
Hall Hall
Komentarze do niniejszej Instrukcji